. Dual DSP Control for best performance
· Green power UPS, A/C-A/C
· Very wide input range -40 % + 25%
· Standard ECO Mode and EPO features.
. Parallel Redundant configuration for 6 units
Input Voltage: 3 x 380,400,415 +N+Gnd
Input Voltage range: - 60, + 25%
Input power Factor: > 0.99
Input Frequency: 40 – 70 Hz
Input THDi < 3% at full load.
Output Voltage: 3 x 380,400,415 +N+Gnd
Power factor: Unity
Frequency: 50 / 60 + 0.1 Hz ( free running)
Output Distortion: < 1% linear Load
< 3 % Non Linear Load
Overload Capability: 115-130% for 15 mins.
: 130 – 150% for 1 mins.
ECO Mode : Standard
Operating Temperature 0-40 deg C
Altitude 0 – 2000 mtrs @ 100% Load.
Noise (dB) 10 -20 Kwatts < 55 dBA
30 – 40 Kwatts < 50 dBA
Protection IP-20
Relative Humidity 0-95%, non condensation.
- Telecommunications -
- Local Area Networks.
- E- business.
- Security systems.
- IT systems.
- Data Centers.
- Medical Applications
Our friendly and knowledgeable staff is always available to answer your questions and provide expert advice.
The maxpro LH UPS is available in 10 -120 kVA On Line double conversion technology.
maxpro LH meeting with VFI-SS-111 classification defined by
IEC EN 62040-3.
maxpro LH is designed to protect critical industrial and Information Technology (IT) systems
. Zero Impact Source
· Low input current distortion - low as 3% and with a 0.99 input power factor;
· Power Walk-In and Start-Up delay to reduce Generator oversizing ;
to help guarantee supply compatibility where available mains power
is limited.
The maxpro LH series also satisfies the following general standards, where applicable:
§ IEC 60529: Degree of protection provided by enclosures;
§ IEC 60664:Insulation for low-voltage equipment;
§ IEC 60755: General Requirements for Residual Current Operated Protective Devices;
§ IEC 60950: General safety provisions for Information Technology
equipment;
§ IEC 61000-2-2: Electromagnetic compatibility immunity;
§ IEC 61000-4-2: Electrostatic discharge immunity test;
§ IEC 61000-4-3: Radio frequencies, electromagnetic immunity test;
§ IEC 61000-4-4 :Transitory overvoltage immunity test;
§ IEC 61000-4-5 :Overvoltage immunity test;
§ IEC 61000-4-11:Voltage dips, short interruptions and voltage variations
immunity test.
§ IEC 61000-3-12: Harmonic current emissions (for equipment with rated
current > 16 A ≤ 75)
Input:
Voltage 320 -480 VAC at full load
Frequency 40 - 72 Hz
THDi < 3%
P.F. 0.99
Output:
Power at PF 0.9
Voltage 380 - 400 - 415 VAC +/- 0.5%
THDv < 1% at linear load
< 3% at Non linear load